Summary0001859: ResampleDTI does not handle the measurement frame
Description

ResampleDTI does not handle the measurement frame when resampling tensors. If the measurement frames is not the identity, then the resampling algorithm does not work well

TagsNo tags attached.

Relationships

related to 0002466 closedinorton CLIs that use DVW nodes crash in MRMLIDImageIO 
related to 0003000 closedfbudin Resample ScalarVectorDWI Volume fails to resample with specified resolution 

Activities

demian

demian

2013-01-10 07:17

developer   ~0007654

Waiting from feedback from the module developer François Budin

pieper

pieper

2013-07-16 11:17

administrator   ~0009074

Francois: is this something you will be able to look at?

fbudin

fbudin

2013-07-17 11:45

developer   ~0009107

ResampleDTI is suppose to handle the measurement frame properly. It may appear that it does not if one only look at the output image and sees that the measurement frame is the identity. However, this is the case because when one resamples a DTI with ResampleDTI, the measurement frame matrix is used in addition of the transform matrix to rotate the tensors. Therefore, once applied, the resulting tensors are in the identity measurement frame.
However, there could be a bug somewhere. Is it possible to have a dataset on which a problem was detected to try to reproduce the bug?

fbudin

fbudin

2014-06-27 05:33

developer   ~0012103

No data was given to reproduce the problem.

Issue History

Date Modified Username Field Change
2012-04-05 09:56 demian New Issue
2012-04-05 09:56 demian Status new => assigned
2012-04-05 09:56 demian Assigned To => demian
2012-04-05 14:05 demian Summary ResampleDTI does not copy the measurement frame => ResampleDTI does not handle the measurement frame
2012-04-05 14:05 demian Description Updated
2012-08-22 05:56 jcfr Target Version => Slicer 4.3.0
2013-01-10 07:17 demian Note Added: 0007654
2013-01-10 07:17 demian Status assigned => feedback
2013-01-10 07:58 demian Relationship added related to 0002466
2013-03-11 13:48 demian Relationship added related to 0003000
2013-07-16 11:17 pieper Status feedback => assigned
2013-07-16 11:17 pieper Assigned To demian => fbudin
2013-07-16 11:17 pieper Note Added: 0009074
2013-07-17 11:45 fbudin Note Added: 0009107
2013-09-03 10:41 jcfr Target Version Slicer 4.3.0 => Slicer 4.3.1
2013-10-04 00:52 jcfr Target Version Slicer 4.3.1 => Slicer 4.3.2
2014-03-06 10:15 nicole Target Version Slicer 4.3.2 => Slicer 4.4.0
2014-06-27 05:33 fbudin Note Added: 0012103
2014-06-27 05:33 fbudin Status assigned => closed
2014-06-27 05:33 fbudin Resolution open => unable to reproduce