View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0003952 | Slicer4 | Module DICOM | public | 2015-02-04 10:06 | 2015-09-09 08:29 |
Reporter | pinter | Assigned To | fedorov | ||
Priority | normal | Severity | minor | Reproducibility | N/A |
Status | closed | Resolution | fixed | ||
Product Version | Slicer 4.4.0 | ||||
Target Version | Fixed in Version | Slicer 4.5.0-1 | |||
Summary | 0003952: Improve DICOM reference loader | ||||
Description | There is a popup window that appears if the loaded DICOM objects have a reference to DICOM instances that can be found in the database. However there are some issues to fix so that this feature is actually usable.
| ||||
Tags | No tags attached. | ||||
solution proposed: https://github.com/Slicer/Slicer/pull/234 |
|
Fixed in: http://viewvc.slicer.org/viewvc.cgi/Slicer4?view=revision&revision=24015 |
|
Looks good, thanks a lot! |
|
Date Modified | Username | Field | Change |
---|---|---|---|
2015-02-04 10:06 | pinter | New Issue | |
2015-02-04 10:06 | pinter | Status | new => assigned |
2015-02-04 10:06 | pinter | Assigned To | => pieper |
2015-02-06 08:50 | fedorov | Assigned To | pieper => fedorov |
2015-02-06 08:58 | fedorov | Note Added: 0012899 | |
2015-03-04 11:15 | jcfr | Note Added: 0012964 | |
2015-03-04 11:15 | jcfr | Status | assigned => resolved |
2015-03-04 11:15 | jcfr | Fixed in Version | => Slicer 4.4.1 |
2015-03-04 11:15 | jcfr | Resolution | open => fixed |
2015-03-17 11:39 | pinter | Note Added: 0012976 | |
2015-03-17 11:39 | pinter | Status | resolved => closed |
2015-09-09 08:29 | jcfr | Fixed in Version | Slicer 4.4.1 => Slicer 4.5.0-1 |