Summary0001582: NCI raycaster is not updating after transform is changed
Description

a volume rendered data set is under a linear transform. NCI gpu render engine is selected. upon change of the transform, the slices are moved but not the VR (see first image). After selecting the gpu ray caster, the VR is updated as well.

TagsNo tags attached.

Activities

2011-11-25 02:41

 

2011-11-25 02:41

 

kikinis

kikinis

2011-11-25 02:43

developer   ~0003386

It seems that changing the render engine gets them to update the effect of changing transform

kikinis

kikinis

2011-11-25 02:44

developer   ~0003387

That means it does not matter which one you start with, the ignore changes in transform until you change to another one.

finetjul

finetjul

2011-11-25 05:19

administrator   ~0003390

Fixed in r18764:
http://viewvc.slicer.org/viewvc.cgi/Slicer4?view=revision&revision=18764

Issue History

Date Modified Username Field Change
2011-11-25 02:41 kikinis New Issue
2011-11-25 02:41 kikinis Status new => assigned
2011-11-25 02:41 kikinis Assigned To => finetjul
2011-11-25 02:41 kikinis File Added: Screen Shot 2011-11-25 at 7.37.31 AM.png
2011-11-25 02:41 kikinis File Added: Screen Shot 2011-11-25 at 7.37.58 AM.png
2011-11-25 02:43 kikinis Note Added: 0003386
2011-11-25 02:44 kikinis Note Added: 0003387
2011-11-25 05:19 finetjul Note Added: 0003390
2011-11-25 05:19 finetjul Status assigned => resolved
2011-11-25 05:19 finetjul Fixed in Version => Slicer 4.0 RSNA
2011-11-25 05:19 finetjul Resolution open => fixed
2012-02-22 05:22 kikinis Status resolved => closed
2012-08-21 09:43 jcfr Target Version => Slicer 4.0.0