Summary0000458: Scalar range in window/level GUI does not update automatically
Description

I have seen this with DTI scalars for vis of DTI. I have also seen unusual update issues with the win/level GUI watching Jean-Jacques use slicer3. My specific reproducible bug is:

  1. Load DWI and create tensors
  2. Go to display properties.
  3. Select some scalar (ex. trace). Images update in slice windows.
  4. Select another scalar. Images change in slice windows. Window/level GUI does NOT update to reflect the new data. To make the GUI update one must select "Auto" again for the window/level (though this was already the current setting)
Additional Information

Fixed updating window/level when changing scalar selection for DTI volume
At revision: 8845

TagsNo tags attached.

Activities

2009-02-24 09:28

 

bug2.tar (675,840 bytes)

Issue History

Date Modified Username Field Change
2009-02-24 09:28 lauren New Issue
2009-02-24 09:28 lauren File Added: bug2.tar
2009-03-04 12:17 pieper Assigned To => alexy
2009-03-04 12:17 pieper Severity minor => major
2009-03-04 12:17 pieper Status new => assigned
2009-03-06 06:28 alexy Status assigned => resolved
2009-03-06 06:28 alexy Resolution open => fixed
2009-03-06 06:28 alexy Additional Information Updated
2010-03-23 10:37 pieper Status resolved => closed