View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0004102 | Slicer4 | Module LabelStatistics | public | 2015-12-06 22:40 | 2017-06-10 01:14 |
Reporter | Tob | Assigned To | lassoan | ||
Priority | normal | Severity | crash | Reproducibility | always |
Status | resolved | Resolution | no change required | ||
Product Version | Slicer 4.5.0-1 | ||||
Target Version | Fixed in Version | ||||
Summary | 0004102: an error about the module “label statistics” | ||||
Description | There was an error when the module “label statistics” quantify the pixels of the three-dimensional images. It only counts the pixels of each 2d image, but not counting the pixels of the images in image spacing. For example, two layers of images are selected for 3D reconstruction , no matter the image spacing is 5 or 50?the statistical results do not change. The result is the sum of two layer images pixels, not containing the pixels of the images in image spacing. | ||||
Additional Information | The below file provide a set of steps and some sample data. | ||||
Tags | No tags attached. | ||||
2015-12-06 22:40
|
a bug.doc (39,424 bytes) |
Measured volume is limited to the region that intersects with the grayscale volume. If spacing of the grayscale volume is unchanged, then thickening of the labelmap will have no effect on the computed volume. If segmentations are created using Segment Editor, volume can be computed using Segment Statistics module. This new module computes both total volume of the segments and volume of parts that overlap with the grayscale volume. |
|
Date Modified | Username | Field | Change |
---|---|---|---|
2015-12-06 22:40 | Tob | New Issue | |
2015-12-06 22:40 | Tob | File Added: a bug.doc | |
2017-06-10 01:14 | lassoan | Assigned To | => lassoan |
2017-06-10 01:14 | lassoan | Status | new => resolved |
2017-06-10 01:14 | lassoan | Resolution | open => no change required |
2017-06-10 01:14 | lassoan | Note Added: 0014726 |